Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
Voltage, Current, Power Factor and Frequency measurements
Power analysis (Active, Apparent and Reactive power)
Energy analysis (Active, Apparent and Reactive power)
Active power accuracy: ±0.3%rdg±0.2%f.s.
Automatic wiring check function to prevent incorrect connections
Large memory capability (2GB) using built-in SD card interface
Real time & remote measurements using Android application
synchronous measurements between two units of KEW 6305
Wide selection of clamp sensors allow measurements from 0.1A to 3000A
The instrument automatically recognizes what kind of clamp sensor is connected to it
6305
 
CE
Windows software for data analysis and setting via USB port or Bluetooth
 

Free Android software "KEW smart 6305" is available
on "Google Play Store" (*)
Supporting Android ver. 2.2 - 3.2

(*) Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.
NEW TRUE RMS USB Bluetooth ®
Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
Measurements Voltage, Current, Frequency, Active power
Parameters Apparent power, Reactive power, Active energy, Apparent energy,
Reactive energy, Power factor (cos θ), Neutral current
Voltage :
Ranges [RMS] 150.0 / 300.0 / 600.0V
Allowable input 10~110% of rating range
Display ranges 5~130% of each range
Accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS]
8128 ( 50A  type ) : 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto
8127 ( 100A  type ) : 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto
8126 ( 200A  type ) : 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto
8125 ( 500A  type ) : 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto
8124 ( 1000A  type ) : 20.00 / 100.0 / 200.0 / 500.0 / 1000A / auto
8129 ( 3000A  type ) : 300.0 / 1000 / 3000A
Allowable input 10~110% of each range
Display ranges 1~130% of each range
Accuracy ±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz)
(*) +1%f.s. at the lowest range
Crest factor Voltage: up to 2.5, Current: up to 3.0 (with 90% fs or less)
Active power accuracy ±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(*) +1%f.s. when the lowest current ranges is selected.
Effect of power factor Active power: ±1.0%rdg cos θ=±0.5 (PF=1)
Frequency meter range 40.0~70.0Hz
Frequency meter accuracy ±3dgt
Accuracy precondition PF=1, Sine wave, 45~65Hz, 23ºC±5ºC
Display update period 1 second
Operating temperature and humidity range 0~+50ºC, less than 85%RH (without condensation)
Storage temperature and humidity range -20~+60ºC, less than 85%RH (without condensation)
PC communication interface USB, Bluetooth
PC card interface SD card (2GB)
Applicable standards IEC 61010-1 CAT.III 600V
Power supply (AC Line) AC100~240V±10% (50/60Hz)
Power supply (DC battery) LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included),
Battery life approx. 15h (LR6)
Power consumption 10VA (max.)
Dimension 175(L)×120(W)×65(D) mm
Weight Approx. 800g (including batteries)
Accessories 7141B (Voltage test lead set: 4pcs)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
8326-02 (SD card 2GB)
KEW WINDOWS (PC Software)
Battery (LR6)×6
Quick manual
Calibration certificate
Optional 8124, 8125, 8126, 8127, 8128 (Clamp sensor)
8129 (Flexible clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetic carrying case)
 
 Set Model
 
KEW 6305-01
  KEW 6305 × 1
  MODEL 8125 × 3
  7141B (Voltage test lead set: 4pcs) × 1
  7148 (USB cable) × 1
  7170 (Power cord) × 1
  8326-02 (SD card [2GB]) × 1
  9125 (Carrying case) × 1
  PC Software × 1
  Battery × 6
  Quick manual × 1
  Calibration certificate

 

MODEL

6300

 
 
 

12 kinds of power measurements
Voltage (RMS), Current (RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cos θ), frequency , demand measurement, current flowing on the neutral line
(Only on 3 phase 4 wire measurement)

Regenerative electric power can be measured
Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated by private power generator, and is supplied to electric power company.

Display 3 different data simultaneously on large screen.

4 types wiring system
1 phase - 2 wire (1ch) (2ch), (3ch)
1 phase - 3 wire
3 phase - 3 wire
3 phase - 4 wire
6300
CE
 

Recording internal can be set between 1 second and 1 hour
  1/2/5/10/15/20/30 second/seconds 1/2/5/10/15/20/30 minute/minutes 1 hour

Demand measurement
  Buzzer sounding and backlight blinking give warning not to exceed the pre-setting demand target value.

Double power supply system AC line and Alkaline size AA battery LR6 : 6 pcs.
  Continuous 7 hours can be measured by using batteries

Supplied with interface software for downloading data to PC via USB.

Direct communication with PC by USB connection

The interface for compact flash card (CF card) is equipped.
  An external memory up to 8GB or less can be used.

Back light function

Designed to Safety Standard IEC 61010-1 CAT.III 600V.

TRUE RMS
 
Measurements and parameters Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, *Reactive energy, Power factor
(cos θ), Neutral current, Frequency meter.
Wiring connections 1P 2W, 3P 4W, 3P 3W, 1P 3W
Voltage :
Ranges [RMS] 150 / 300 / 600V (CF: 2.5 or less)
Allowable input 10~110% of each range
Display ranges 5~120% of each range
Accuracy |±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS]
8128 ( 50A  type ) : 5 / 10 / 20 / 50A
8127 ( 100A  type ) : 10 / 20 / 50 / 100A
8126 ( 200A  type ) : 20 / 50 / 100 / 200A
8125 ( 500A  type ) : 50 / 100 / 200 / 500A
8124 ( 1000A  type ) : 100 / 200 / 500 / 1000A
8129 ( 3000A  type ) : 1000 / 3000A
(CF:3.0 or less. 90% or less of each range)
Allowable input 10~110% of each range
Display ranges 1~120% of each range
Accuracy |±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(sine wave, 45~65Hz)
Activa power accuracy |±0.5%rdg±0.2%f.s. + Accuracy of Clamp sensor
(Power factor 1, Sine wave, 45~65Hz)
Frequency meter range 40~70Hz
Frequency meter accuracy |±3dgt
Effect of power factor Active power : ±1.0% rdg cos θ=±0.5 (PF=1)
Integration time for recording function 1/2/5/10/15/20/30 Seconds 1/2/5/10/15/20/30/60 Minutes
Display update period 1 second
Operating temperature and humidity ranges 0~+50ºC, less than 85% RH (without condensation)
Storage temperature and humidity ranges -20~+60ºC, less than 85% RH (without condensation)
Over load protection Voltage : 720V AC rms
Current : 600A AC rms (with Clamp sensor MODEL 8125)
PC communication Interface USB
CF card Interface Compact flash card
(Standard type 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB)

* The CF card larger than 2GB is usable, however, the possible stored size will be limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maximum stored size will be 2GB.
Safety standard IEC 61010-1 CAT.III 600V
Power supply AC Line : 100~240V±10% (50/60Hz)
DC Battery 9V : LR6×6(Battery life approx. 7h)
Power consumption 10VA (MAX)
Dimension 175(L)×120(W)×65(D) mm
Weight Approx. 800g (including batteries)
Accessories 7141B (Voltage test lead set),
7148 (USB Cable),
7170 (Power cord),
8307 (Compact Flash card 128MB),
8319 (CF Card reader),
9125 (Carrying bag),
PC Software, Batteries × 6, Quick manual
Optional accessories

8124,8125,8126,8127,8128 (Load Current Clamp Sensor).
8129 (Flexible Clamp Sensor).
8312 (Power supply adaptor)
8322 (Compact flash card 256MB)
8323 (Compact flash card 1GB)
9132 (Carrying case with magnet)
Wide range of clamp sensor up to 1000A on request.

* PC OUTPUT only
* Please refer to here for the CF cards which checked.
 
Set Model
MODEL 6300-01
Consists of:
MODEL 6300 × 1
MODEL 8125(Φ40) × 3
MODEL 6300-02
Consists of:
MODEL 6300 × 1
MODEL 8125(Φ40) × 2
     
MODEL 6300-03
Consists of:
MODEL 6300 × 1
MODEL 8124(Φ68) × 3
 
MODEL 6300-04
Consists of:
MODEL 6300 × 1
MODEL 8124(Φ68) × 2
     
MODEL 6300-05
Consists of:
MODEL 6300 × 1
MODEL 8126(Φ40) × 3
 
MODEL 6300-06
Consists of:
MODEL 6300 × 1
MODEL 8126(Φ40) × 2
     
MODEL 6300-07
Consists of:
MODEL 6300 × 1
MODEL 8127(Φ24) × 3
 
MODEL 6300-08
Consists of:
MODEL 6300 × 1
MODEL 8127(Φ24) × 2
     
MODEL 6300-09
Consists of:
MODEL 6300 × 1
MODEL 8128(Φ24) × 3
 
MODEL 6300-10
Consists of:
MODEL 6300 × 1
MODEL 8128(Φ24) × 2
     
Accessories
7141B (Voltage test lead set) × 1
7148 (USB Cable) × 1
7170 (Mains Cord) × 1
8307 (Compact Flash card 128MB) × 1
8319 (CF Card reader)
9125 (Carrying bag) × 1
PC Software × 1
Batteries × 6
Quick manual × 1
 

Power Quality Analyzer

 

KEW

6310

 
 
 
Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured.
12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis.
One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory.
Direct communication with PC via USB cable
6310
CE
Built-in Input / Output Function of external signal enables the signal transmission to alarms.
2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function.
Pull / Insert of CF card possible whenever on recording under the function of memory backup device.
Can monitor insulation at leakage current by using optional leak clamp sensors.
Built-in Print Screen Function enables to record display screen
(Records 512 screens by using CF card: 1 screen 40KB).
Can display Waveform and Vector, and can confirm the wiring connection, too.
Complies fully with International Safety Standards IEC 61010-1 CAT.III 600V.
* Attention for KEW6310 customers:
 
Flicker measurements are possible with firmware of KEW6310 upgrade (Ver.2.01), PC software PQA Master upgrade (Ver. 2.01) and an optional accessory Flicker sensor KEW8325F.

TRUE RMS
 
Wiring connections 1P 2W, 1P 3W, 3P 3W, 3P 4W
Measurements and parameters Voltage, Current, Frequency, Active power, Reactive power,
Apparent power, Active energy, Reactive energy, Apparent energy,
Power factor (cos θ), Neutral current, Demand, Harmonics,
Quality (Swell/Dip/Instantaneous Stop, Transients/Over Voltage, Inrush Current, Unbalance Rate, IEC Flicker [Pst(1 min)*, Pst, Plt]), Phase Advance Condenser

(*Pst can be shown in details for 1 minute intervals.)
Other functions Digital output function, External communication function,
Scaling function
Voltage :
Ranges [RMS] 150 / 300 / 600 /1000V (CF: 2.5 or less, 100% or less of each range)
Allowable input 10~110% of each range (1000V range : 20%~)
Display ranges 5~120% of each range
Accuracy |±0.3%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current :
Ranges [RMS]
8128 ( 50A  type ) : 1 / 5 / 10 / 20 / 50A
8127 ( 100A  type ) : 10 / 20 / 50 / 100A
8126 ( 200A  type ) : 20 / 50 / 100 / 200A
8125 ( 500A  type ) : 50 / 100 / 200 / 500A
8124 ( 1000A  type ) : 100 / 200 / 500 / 1000A
8129 ( 3000A  type ) : 300 / 1000 / 3000A
(CF:3.0 or less. 90% or less of each range)
Allowable input 10~110% of each range
Display ranges 1~120% of each range
Accuracy |±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(sine wave, 45~65Hz)
Activa power accuracy |±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor
(Power factor 1, Sine wave, 45~65Hz)
Influence of power factor |±1.0%rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range 40~70Hz
Internal memory
1.8MB    
Measurement file (CSV) : 256kB×6 blocks (=1.536MB)
Screen file (BMP) : 32kB×7 blocks (=0.224MB)
Configuration file (KAS) : 32kB
Display 320×240 (RGB) Pixel, 3.5-inch color STN display
Temperature & humidity range 23ºC±5ºC, Relative humidity 85% or less (no condensation)
Storage Temperature & humidity range -20ºC±60ºC, Relative humidity 85% or less(no condensation)
Operating Temperature & humidity range 0ºC±40ºC, Relative humidity 85% or less(no condensation)
PC Card type *1 Compact flash card
(Capacity: 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB)

* The CF card larger than 2GB is usable, however, the possible stored size will be limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maximum stored size will be 2GB.
Applicable standards IEC 61010-1 CAT.III 600V Pollution degree 2
IEC 61010-031, IEC 61326
Power supply AC 100V ~ 240V±10% (45~65Hz)
Alkaline size AA battery LR6 (9V 1.5V × 6) or Ni-MH (HR15-51)
Dimension 175(L)×120(W)×68(D) mm
Weight approx. 900g (including batteries)
Accessories 7141B (Voltage test lead set)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
8307 (Compact flash card 128MB)
8319 (CF Card reader)
Input terminal plate (6-kind)
Alkaline size AA battery (LR6) × 6
PQA MASTER (PC Software)
Quick manual
Cable marker × 32
Optional accessories 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)
8129 (Flexible clamp sensor)
8146, 8147, 8148 (Leakage & Load current clamp sensor) *2
8141, 8142, 8143 (Leakage clamp sensor) *2
8322 (Compact flash card 256MB)
8323 (Compact flash card 1GB)
8312 (Power supply adaptor)
8325F (Flicker sensor)
9132 (Carrying case (for instrument))
*1: Please refer to here for the CF cards which checked.
*2: Cannot be used for power measurement.
 
 Set Model

MODEL Clamp Sensor
KEW 6310-01 8125 (500A) × 3
KEW 6310-02 8125 (500A) × 2
KEW 6310-03 8124 (1000A) × 3
KEW 6310-04 8124 (1000A) × 2
KEW 6310-05 8126 (200A) × 3
KEW 6310-06 8126 (200A) × 2
KEW 6310-07 8127 (100A) × 3
KEW 6310-08 8127 (100A) × 2
KEW 6310-09 8128 (5A) × 3
KEW 6310-10 8128 (5A) × 2
KEW 6310-11 8129-03 × 1
KEW 6310-12 8129-02 × 1


 Accessories
 
6310 × 1
7141B (Voltage test lead set)
7148 (USB cable)
7170 (Power cord)
9125 (Carrying case)
PQA MASTER (PC Software)
Input terminal plate (6-kind)
Quick manual
Alkaline size AA battery (LR6) × 6
8307 (Compact flash card 128MB)
Cable marker × 32
8319 (CF Card reader)
You are here:   HomePOWER METERS

OFFICE

  • Head Office : Kota Wisata, Ruko Concordia SRB26 Cileungsi, Bogor, Jawa Barat 16969
  • Calibrating Service : Kota Wisata, Ruko Boston RK3 No. 9-10 Cileungsi, Bogor, Jawa Barat 16969

STORE

  • Plaza Kenari Mas , Lt. LG Blok B121 , Jalan Kramat Raya No. 101 , Paseban , Senen , Jakarta Pusat 10440 , Phone : 021-29478925
  • LTC , Jl. Hayam Wuruk No.127, Mangga Besar, Tamansari, Kota, Jakarta Barat 11180

Kyoritsu Indonesia by PT. Best Instrument Indonesia | Ruko Concordia SRB 26, Kota Wisata Cibubur, Cileungsi, Bogor - Indonesia.