Kyoritsu Indonesia - Digital Multimeters KEW MATE 2012R


Kyoritsu Indonesia : Multimeters,Voltage Tester,Clamp Meters,Insulation Testers, Earth Testers,Loop/PSC/RSD Testers,Loggers,Multi Function Testers,Portable Appliance Testers,Power Meters,Others, Sensors


 

KEW MATE

2012R

 
Selection Guide Product Catalogue Instruction Manual
 
Innovative Multhimeters with current measurements up to 120A AC/DC
Unique Open Jaw technology for AC/DC current measurements
Very compact and as reliable as a tradictional full size multimeter

NEW TRUE RMS
Φ12 MAX AC/DC 120A ACV DCV
Ω Continuity Hz Diode
Capacitance  
2012R

CE

 
DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 ~ 400Hz)
DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A
±2.0%rdg±5dgt (45 ~ 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 35±25Ω
Diode test 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt
Frequency
(AC A) 100/1000Hz/10kHz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10kHz)
 
(DC A) 100/1000Hz/10/100/300.0kHz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
 
(Input sensitivity
Current: more than 2A
Voltage: more than 2V [~10kHz]/more than 20V [10k~300kHz])
Conductor size Ø12mm max.
Withstand voltage 3540V AC for 5 seconds
Applicable standards IEC 61010-1 CAT.III 300V, CAT.II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326
Power source
R03 (1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mm
Weight 220g approx. (including batteries)
Accessories R03 (1.5V) × 2, Instruction manual
Optional 9107 (Carrying case [Soft])

Quick Contact






618987
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
92
228
1095
616709
5015
6337
618987

Your IP: 54.80.146.251
Server Time: 2017-11-24 07:34:34
You are here:   HomeKyoritsuMultimetersDigital Multimeter KEW MATE 2012R

OFFICE

  • Head Office : Kota Wisata, Ruko Concordia SRB26 Cileungsi, Bogor, Jawa Barat 16969
  • Calibrating Service : Kota Wisata, Ruko Boston RK3 No. 9-10 Cileungsi, Bogor, Jawa Barat 16969

STORE

  • Plaza Kenari Mas , Lt. LG Blok B121 , Jalan Kramat Raya No. 101 , Paseban , Senen , Jakarta Pusat 10440 , Phone : 021-29478925
  • LTC , Jl. Hayam Wuruk No.127, Mangga Besar, Tamansari, Kota, Jakarta Barat 11180

Kyoritsu Indonesia by PT. Best Instrument Indonesia | Ruko Concordia SRB 26, Kota Wisata Cibubur, Cileungsi, Bogor - Indonesia.