Kyoritsu Indonesia - Leakage Clamp Meters 2432,2433,2433R, 2434


Kyoritsu Indonesia : Multimeters,Voltage Tester,Clamp Meters,Insulation Testers, Earth Testers,Loop/PSC/RSD Testers,Loggers,Multi Function Testers,Portable Appliance Testers,Power Meters,Others, Sensors


 

Leakage Clamp Meters

MODEL

2432

 
Selection Guide Product Catalogue Instruction Manual
 

High Sensitive Model
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges : 4mA/40mA/100A

Ø40 ØMAXAC100A Resolution 0.001mA Filter
PEAK 10ms      
2432
CE
 
AC A
(50/60Hz)
4/40mA/100A
|±1%rdg±5dgt (4/40mA)
|±1%rdg±5dgt (0~80A)
|±5%rdg (80.1~100A)
AC A
(WIDE)
4/40mA/100A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz~1kHz] (4/40mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz~1kHz] (0~80A)
|±5%rdg [50/60Hz],
|±10%rdg [40Hz~1kHz] (80.1~100A)
Frequency Response 20Hz~1kHz (40Hz~1kHz:100A)
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø40mm max.
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-032
Effect of External
Stray Magnetic Field
2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Withstand Voltage 3700V AC for 1 minute
Response Time Approx. 2 seconds
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 290g approx.
Accessories 9052 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual
Optional 8008 (Multi-Tran)*
* This Multi-Tran can not be used for leakage current measurement

 


 

Leakage Clamp Meters

MODEL

2433

 
Selection Guide Product Catalogue Instruction Manual
 

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges : 40mA/400mA/400A.

Ø40 MAX AC400A Resolution 0.01mA Filter
PEAK 10ms      
2433
CE
 
AC A
(50/60Hz)
40/400mA/400A
|±1%rdg±5dgt (40/400mA)
|±1%rdg±5dgt (0~350A)
|±2%rdg (350.1~399.9A)
AC A
(WIDE)
40/400mA/400A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz~1kHz] (40/400mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz~1kHz] (0~350A)
|±2%rdg [50/60Hz],
|±5%rdg [40Hz~1kHz] (350.1~399.9A)
Frequency Response 20Hz~1kHz (40Hz~1kHz:400A)
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø40mm max.
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-032
Effect of External
Stray Magnetic Field
10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Withstand Voltage 3700V AC for 1 minute
Response Time Approx. 2 seconds
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 270g approx.
Accessories 9052 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual
Optional 8008 (Multi-Tran)*
* This Multi-Tran can not be used for leakage current measurement

 


 

Leakage Clamp Meters

MODEL

2433R

 
Selection Guide Instruction Manual
 

Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:
40mA/400mA/400A.

TRUE RMS
Ø40 MAX AC400A Resolution 0.01mA Filter
PEAK 10ms      
2433R
CE
 
AC A
(50/60Hz)
40/400mA/400A
|±1%rdg±5dgt (40/400mA)
|±1%rdg±5dgt (0~300A)
|±2%rdg (300.1~399.9A)
AC A
(WIDE)
40/400mA/400A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz~1kHz] (40/400mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz~1kHz] (0~300A)
|±2%rdg [50/60Hz],
|±5%rdg [40Hz~1kHz] (300.1~399.9A)
Frequency Response 20Hz~1kHz [40Hz~1kHz:400A]
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø40mm max.
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-032
Effect of External
Stray Magnetic Field
10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Withstand Voltage 3700V AC for 1 minute
Response Time Approx. 2 seconds
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 270g approx.
Accessories 9052 (Carrying Case) R03 (1.5V) × 2
Instruction Manual
Optional 8008 (Multi-Tran)*
* This Multi-Tran can not be used for leakage current measurement

 


 

Leakage Clamp Meters

MODEL

2434

 
Selection Guide Product Catalogue Instruction Manual
 

Least affected by external stray magnetic field.
20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
Frequency Selector Switch to eliminate the effect of harmonics.

Ø28 MAX AC100A Resolution 0.1mA Filter
2434
CE
 
AC A (50/60Hz) 400mA/4/100A ±2%rdg±4dgt
AC A (WIDE) 400mA/4/100A
|±2%rdg±4dgt [50/60Hz]
|±3%rdg±5dgt [40~400Hz]
Conductor Size Ø28mm max.
Safety Standard IEC 61010-1 CAT.III 300V IEC 61010-2-032
Effect of External
Stray Magnetic Field
Ø15mm 100A
20mA AC max.
Frequency Response 40~400Hz
Withstand Voltage 3700V AC for 1 minute
Power Source R03 (AAA) (1.5V) × 2
Dimensions 169(L) × 75(W) × 40(D)mm
Weight 220g approx.
Accessories Carrying Case
R03 × 2
Instruction Manual
Optional 8008 (Multi-Tran)*
* This Multi-Tran can not be used for leakage current measurement.

 


 

Quick Contact






You are here:   HomeKyoritsuClamp MetersLeakage 2432,2433,2433R,2434

OFFICE

  • Head Office : Kota Wisata, Ruko Concordia SRB26 Cileungsi, Bogor, Jawa Barat 16969
  • Calibrating Service : Kota Wisata, Ruko Boston RK3 No. 9-10 Cileungsi, Bogor, Jawa Barat 16969

STORE

  • Plaza Kenari Mas , Lt. LG Blok B121 , Jalan Kramat Raya No. 101 , Paseban , Senen , Jakarta Pusat 10440 , Phone : 021-29478925
  • LTC , Jl. Hayam Wuruk No.127, Mangga Besar, Tamansari, Kota, Jakarta Barat 11180

Kyoritsu Indonesia by PT. Best Instrument Indonesia | Ruko Concordia SRB 26, Kota Wisata Cibubur, Cileungsi, Bogor - Indonesia.